Parts of a stair
- Riser: the height you climb from one step to the next.
- Tread (where your foot lands): the horizontal surface you step on; its depth is measured horizontally from nosing to nosing.
- Flight: an uninterrupted run of steps between two landings or two floors.
- Landing: the level area between flights or at their start.
- Handrail: the rail you hold with your hand; the guard is the part that prevents falls from an open edge.
- Headroom: the clear height from the top of a tread up to the ceiling or the slab above.
The 2R + G rule: why are the riser and tread chosen together?
The riser and tread are chosen together, because a step on stairs is shorter than a step on level ground, and it goes both up and forward. That’s why the sum of the riser and tread is kept within a certain range: 2 × riser + tread. If the riser gets bigger, the tread gets smaller; if the riser gets smaller, the tread gets bigger.
- Türkiye: 2 × riser + tread = 60–64 cm; tread at least 27 cm; riser at most 16 cm in buildings without an elevator and at most 18 cm in buildings with an elevator (Planned Areas Zoning Regulation, article 31/2).
- England: 2R + G = 550–700 mm; for stairs in a single dwelling, riser 150–220 mm, tread (going) 220–300 mm and a pitch of at most 42° (Approved Document K).
- US: riser at most 7¾ in (196 mm), tread at least 10 in (254 mm) (IRC R311.7).
In Türkiye, tread nosings must not project (article 31/2-ç). Within a flight, risers and treads are kept equal; in the US, the difference between the tallest and shortest riser in a flight may be at most ⅜ in (9.5 mm).
How many steps do you need from floor to floor?
The calculation takes two steps; for example, a 300 cm floor-to-floor height with a 16 cm riser limit gives 19 risers and 18 treads. First, divide the floor-to-floor height (slab to slab, including the slab thickness) by the maximum riser and round up: that’s the number of risers. Then choose the tread to fit the 2R + G range. There is one tread fewer than risers; the horizontal length of the flight is the number of treads × the tread depth.
| Floor to floor | Riser | Tread | 2 × riser + tread | Horizontal flight length |
|---|---|---|---|---|
| 280 cm | 18 × 15.6 cm | 17 × 31 cm | 62.1 cm | 527 cm |
| 300 cm | 19 × 15.8 cm | 18 × 30 cm | 61.6 cm | 540 cm |
| 320 cm | 20 × 16.0 cm | 19 × 30 cm | 62.0 cm | 570 cm |
| 300 cm (building with an elevator) | 17 × 17.6 cm | 16 × 28 cm | 63.3 cm | 448 cm |
The first three rows are calculated with Türkiye’s limit for buildings without an elevator (riser at most 16 cm). A bigger riser shortens the flight but makes the stairs steeper; if space is tight, splitting the flight in two with a landing in between (L or U stairs) is often the better solution.
How wide should stairs be?
In Türkiye, common stairs in residential buildings must have a flight and landing width of at least 1.20 m, and stairs inside an independent unit (an apartment) at least 1.00 m; common stairs also cannot be narrower than the escape width required by the fire regulation (article 31/1-a). England sets no minimum width for stairs in a single dwelling; the US requires at least 36 in (914 mm).
In Germany, the width depends on state regulations. For example, in Rhineland-Palatinate the usable width of a stair is 1 m, and it may be 0.80 m in small residential buildings and inside an apartment (LBauO § 33).
Stair dimensions by country
| Dimension | Türkiye | England (single dwelling) | USA |
|---|---|---|---|
| Riser | at most 16 cm (no elevator), 18 cm (with elevator) | 150–220 mm | at most 7¾ in (196 mm) |
| Tread | at least 27 cm | 220–300 mm | at least 10 in (254 mm) |
| Step rule | 2 × riser + tread = 60–64 cm | 2R + G = 550–700 mm, at most 42° | no |
| Width | common 1.20 m, inside an apartment 1.00 m | not specified | at least 36 in (914 mm) |
| Headroom | 2.10 m in escape stairs (fire regulation) | 2.0 m | 6 ft 8 in (2032 mm) |
| Handrail | on both sides | 900–1000 mm; on both sides for stairs 1 m wide or more | 34–38 in; on at least one side with 4 or more risers |
The headroom value for Türkiye is the one the Regulation on Fire Protection of Buildings sets for escape stairs (article 41); the zoning regulation gives no headroom for stairs inside an apartment. The same regulation requires escape stairs to have risers of at most 175 mm, treads of at least 250 mm and a landing every 17 steps.
Winder and spiral stairs
If triangular (winder) steps are used instead of a landing where the flight turns, the tread narrows toward the inner end. That’s why the dimension is checked on a particular line, not across the whole tread:
- Türkiye: on winder stairs, the tread is at least 0.10 m at the narrowest edge and at least 0.27 m at the middle of the tread (article 31/2-c).
- England: measured at the middle of the tread on stairs narrower than 1 m, and 270 mm in from both sides on wider stairs; at least 50 mm remains at the narrow end.
- US: a winder tread is at least 10 in at 12 in from the narrow side and nowhere narrower than 6 in. Spiral stairs require a width of at least 26 in, a riser of at most 9½ in and 6 ft 6 in of headroom.
A spiral stair takes up little space but is hard for carrying things and for older people. In Türkiye, the fire regulation limits when a spiral stair can count as an escape stair: width at least 100 cm, height at most 9.50 m, tread at least 250 mm at 50 cm from the center, riser at most 175 mm (article 43).
Landings, guards and the space under the stairs
- Landing: in Türkiye, the flight and landing of common stairs are at least 1.20 m, and in escape stairs the landing is no narrower than the stair width; in England, a landing is at least as wide and as long as the flight is wide; in the US, it is at least 36 in deep and the rise between two landings is at most 151 in.
- Guard: in Türkiye, open stairs with more than one step need a guard at least 1.10 m above the floor on the open edge (article 38). Handrails are on both sides of the stairs (article 31/1-ç).
- Under the stairs: spaces under stairs lower than 1.80 m are closed off (article 31/6), so nobody hits their head.
Drawing stairs in Nodaform
In Nodaform, you place stairs with the Stairs tool (M) in the Shell step: straight stairs on every plan, L and U stairs in Plus, spiral stairs in Pro. The number of risers is calculated automatically from the floor’s clear height and the slab thickness (risers of about 17.5 cm); you change the tread depth in the right panel, and the length of a straight flight becomes the number of treads × the depth.
The panel shows the riser, the tread and the 2 × riser + tread sum, and warns you if the sum falls outside 60–64 cm or the riser outside 15–19 cm. In the plan, stairs are drawn as if cut at 110 cm (dashed above the cut), and a 110 cm guard is placed around the stair opening on the upper floor; in section and 3D, you see the treads, handrail and guard. The editor doesn’t check country rules: for example, check the number of risers against Türkiye’s 16 cm limit for buildings without an elevator in the construction drawings.
The rules in this post were checked against official texts on 20 November 2026 (Planned Areas Zoning Regulation, Regulation on Fire Protection of Buildings, England’s Approved Document K, the US 2021 IRC). Stair dimensions in Germany depend on state regulations and the paid DIN 18065 standard, so they were left out of the table. Before having stairs built, consult your local regulations and your architect.