Accessible step · Accessibility · Free

Accessible home design starts with measurements.

Where does a wheelchair turn, how wide should a door be, at what slope does a ramp rise, how much space should be left beside the toilet? This page explains the basic dimensions of accessible design for Turkey, Germany, the United Kingdom and the US, with sources. Nodaform's Accessible step applies the same dimensions to your plan: turning circles, door widths and the route from the entrance to the rooms appear on the plan, and anything missing is listed.

Compare the dimensions
From official sources, dated · For information only · The check, ramps and accessible objects are free on all plans
Ø150 cmcircle a wheelchair needs to turn
90 cmminimum interior door width in Turkey
5–8%ramp slope by height in Turkey
4 regionsrules with article and date
Accessible · Check · Ground floorTurkey · Housing
%7+45 RAMP · 6.43 m + LANDING 110 76 90 Ø150 Ø150 Ø140 80 cm LIVINGBEDBATH ACCESSIBILITY CHECK Turkey · Accessible housing Entrance 45 cm above ground · ramp in place 3 / 3rooms reachable 2 / 3Ø150 turning space FINDINGS Bedroom doorClear opening ≈ 76 cm;at least 90 cm. BedroomØ150 turning space doesn't fit;largest free area Ø140. Bathroom80 cm beside the toilet;at least 90 cm. Ramp7% · OK for a 45 cm rise.
Six basic dimensions

The six basic dimensions of an accessible home

Accessibility isn't a product; it's a set of dimensions. Whether a home is comfortable for a wheelchair user usually comes down to these six questions, and everyone who has difficulty walking, uses a cane or a walker, or arrives with a pushchair benefits from the same dimensions.

01 · Turning

Ø150 cm clear circle

For a wheelchair to turn on the spot, a clear circle about 150 cm in diameter is needed in the bathroom, kitchen, bedroom and entrance. Germany's basic level and England's bedroom rule accept 120 × 120 cm.

02 · Door

Clear opening width

What matters isn't the size of the door but the clear opening left with the leaf open at 90°. In Turkey, at least 90 cm for interior doors and 100 cm for the apartment's entrance door; in Germany, 90 cm in wheelchair-accessible housing; in the US, 81.5 cm.

03 · Corridor

Width along the route

Halls and corridors are at least 120 cm in Turkey and Germany and 91.5 cm in the US. On the latch side of the door, on the side it opens towards, there should also be free space to approach it: about 50 cm in Turkey, 45.5 cm in the US.

04 · Threshold

No threshold, or a very low one

In Turkey, thresholds aren't allowed at doors; if unavoidable, at most 1.3 cm and bevelled. 2 cm in Germany, 1.5 cm in England, 1.3 cm in the US. The shower should also be flush with the floor.

05 · Ramp

Slope by height

In Turkey, 8% up to 15 cm, 7% up to 50 cm, 6% up to 100 cm and 5% above that. In Germany at most 6% in all cases, in the US 1:12 (8.33%). A long ramp needs intermediate landings.

06 · Bathroom

Transfer space and knee clearance

To transfer from the wheelchair to the toilet, at least 90 cm of space on one side of the toilet; the washbasin and worktop are open underneath, with enough room for the wheelchair user's knees. Seat height 43–48 cm.

Four regions, one table

Accessible design dimensions: comparison by country

The same question gets a different figure in each country. The values below are for homes and are taken from official texts; for Germany, the basic level (barrierefrei) and the fully wheelchair-accessible level (R) are shown separately, and for England, M4(2) and M4(3). Dimensions are in centimetres.

DimensionGermanyUnited KingdomUSA (ADA)Türkiye
Turning space120 × 120 · R: 150 × 150Ø150 (bathroom, entrance); 120 × 120 in the bedroomØ152.5 or T-turnØ150 or 150 × 150
Interior door, clear≥ 80 · R: ≥ 9075–80 (by corridor width) · M4(3): ≥ 85≥ 81,5≥ 90
Apartment entrance door, clear≥ 90≥ 85≥ 81,5≥ 100
Hall and corridor≥ 120≥ 90 · M4(3): ≥ 105≥ 91,5≥ 120
Thresholdnone; if unavoidable ≤ 2≤ 1,5≤ 1,3none; if required ≤ 1.3, bevelled
Ramp slope≤ %61:12 flight ≤ 2 m · 1:15 ≤ 5 m · 1:20 ≤ 10 m≤ 1:12 (%8,33)%8 (≤ 15) · %7 (≤ 50) · %6 (≤ 100) · %5
Ramp flight and landingflight ≤ 600; landing ≥ 150; width ≥ 120landing ≥ 120; width ≥ 90 · M4(3): 120flight rise ≤ 76; landing ≥ 152.5; width ≥ 91.5150 × 150 every 9 m; clear width ≥ 100
Beside the toiletR: 90 wide × 70 deepM4(3): WC centreline 45–50 from the side wall152.5 × 142 around the WC≥ 90 clear on one side
WashbasinR: front edge ≤ 80; knee clearance ≥ 67top edge 77–85≤ 86.5; knee clearance 68.5top ≤ 86; knee clearance ≥ 68.5
In front of worktops≥ 120 · R: ≥ 150≥ 120 · M4(3): ≥ 150≥ 101,5≥ 105 between facing worktops
Beside the bed120 and 90 · R: 150 and 120≥ 75 · M4(3): ≥ 100no separate rule for homesØ150 beside it or at the foot

In Turkey, the binding provisions for the inside of homes (doors, corridors, thresholds, ramps, lifts) are in the Planned Areas Zoning Regulation; the turning space, bathroom, kitchen and bedroom dimensions come from the Ministry of Family and Social Services accessibility guide and are recommendations. In Germany, level R is mandatory only in homes built specifically as wheelchair-accessible; in England, M4(2) and M4(3) are mandatory when the planning permission requires them. In the US, the ADA covers some of the housing of public bodies or businesses open to the public; private single-family homes are outside its scope.

Rules by region

Accessibility rules, article by article

Below we've summarised the rules of the four regions from the official texts, article by article. Other requirements may apply depending on the building type and local regulations; check the current text and your municipality before applying them.

The main sources are the Planned Areas Zoning Regulation (last amended 1 July 2026) and the Ministry of Family and Social Services' Accessibility Guide (2020). The regulation requires buildings and their entrances to comply with TS 9111; the standard itself is paid.

Door
Apartment entrance door at least 100 cm, doors of other rooms at least 90 cm; building entrance door at least 150 cm (with double doors, one leaf at least 100 cm). The guide measures this as the clear opening with the leaf open at 90°; to achieve it, the door opening is left at least 100 cm for interior doors and 110 cm for the apartment door. Art. 39(1) · Guide 5.1–5.2
Threshold
Thresholds aren't allowed at doors. Guide: a level difference of up to 0.6 cm is permitted, 0.6–1.3 cm bevelled at no more than 1:2, and anything more needs a ramp. Art. 39(2) · Guide 1.4
Hall and corridor
At least 120 cm in all buildings, including homes. Art. 29(3)
Ramp
Slope by height: up to 15 cm 8%, 16–50 cm 7%, 51–100 cm 6%, over 100 cm 5%. Clear width at least 100 cm. A 150 × 150 cm landing at the top, at the bottom and at changes of direction; on ramps longer than 9 m, a level rest area every 9 m. Continuous handrails on both sides at 90 and 70 cm. Art. 30(12), 30(13) · Guide 1.5
Building entrance
In the front garden, up to the plot boundary: an entrance ramp, or space next to the stairs for an accessible lift or lifting platform with a short side of at least 0.90 m and an area of at least 1.20 m². Art. 30(9)
Turning space
Ø150 cm or 150 × 150 cm for a wheelchair to turn; in the toilet room, the kitchen, the bedroom and in front of the entrance door. Guide 1.2, 6.1, 12.1, 12.3
Toilet and bathroom
Toilet seat height 43–48 cm; at least 90 cm of clear transfer space on one side, and at least 46 cm between the toilet centreline and the wall on the other; a folding grab bar. Front top edge of the washbasin at most 86 cm, with at least 68.5 cm knee clearance underneath. Shower flush with the bathroom floor, no threshold. Guide 6.2–6.3, 12.2
Kitchen
Worktop surface at most 86 cm (71.5 / 81.5 / 91.5 cm on adjustable worktops); knee clearance at least 90 cm wide, 75 cm high and 49 cm deep, under the hob too. At least 105 cm between facing worktops. Guide 12.1
Bedroom
At least Ø150 cm of manoeuvring space along the side of the bed or at its foot, and in front of the wardrobe too. Bed height 45–50 cm. Guide 12.3
Lift
Space for a lift in a building with 3 storeys including the basement, and a lift with 4 or more storeys. In a building with a single lift, the car's short side at least 1.20 m and its area at least 1.80 m²; door clear width at least 0.90 m. Art. 34(1), 34(2)

Sources: Planned Areas Zoning Regulation · Accessibility Guide (2020) · Accessibility Monitoring and Inspection Form for Buildings · Last checked: 28 October 2026

This section is for information only; it does not replace the regulation itself, an accessibility design or the opinion of a licensed architect, engineer or the authorities. Rules may change; check the current official text before applying them.

The Accessible step in Nodaform

Accessibility check: choose, scan, fix

On the left of the editor, below Safety, is the Accessible step. You choose a rule set; the check measures the distance from every point of the plan to walls and furniture on a 5 cm grid and draws the result on the plan.

Accessibility check · PlanAccessible 2+1
On the Accessible 2+1 plan, the accessibility check: a turning circle in every room, clear door openings, the wheelchair route from the entrance to each room and a ramp at the entrance
Green circles are turning spaces, the blue line is the wheelchair route from the entrance to every room, the labels are the clear door openings.
3D · Plinth 30 cmRamp
In 3D, a single-storey house on a 30 cm plinth and a ramp with handrails on both sides leading up to the entrance door
The building sits on the plinth; the ramp leads from the ground up to the entrance door, with its length and landing calculated for the chosen rule set.
Step 01

Choose a rule set

Turkey, Germany (accessible or wheelchair-accessible), the United Kingdom (M4(2) or M4(3)) or the USA. If the building sits above the site, enter the plinth in the Site step; the entrance height comes from there.

Step 02

See it on the plan

The largest turning circle that fits in each room is drawn in green or red, along with the clear opening of the doors, the approach space on the latch side, the space beside the toilet and the bed, and a wheelchair route from the entrance to each room. Narrow points are marked in centimetres.

Step 03

Fix

Click a finding and the plan jumps to that spot. Widen the door, move the furniture, add a ramp at the entrance: you enter the rise, and the slope, flight length and landings are calculated according to the rule set you chose. Objects such as a washbasin with knee space, grab bars and a level-access shower are in the Accessible living category of Furniture.

Accessible living category · 23 objects

Accessible objects: true to size, in 2D and 3D

Each object is drawn to the size of common products, with a symbol on the plan and a model in 3D. All free. Full list in the Furniture library.

Accessible living · 3D models12 / 23
3D models from the Accessible living category: accessible toilet, counters with knee space, pull-down wardrobe, care bed, patient hoist, wheelchair, rollator, home lift, platform lift and stairlift
Bathroom

Transfer and safety

Accessible toilet (with grab bars, transfer space marked), folding and L-shaped grab bars, folding shower seat, 150 × 150 cm level-access shower area, washbasin with knee space and tilted mirror, emergency call button with pull cord.

Kitchen

Worktops with knee space

Sink worktop with knee space (85 cm, open underneath up to 75 cm), hob worktop with front controls, height-adjustable kitchen worktop, pull-down wall cabinet.

Bedroom

Care and access

Height-adjustable home care bed (side rails, lifting pole), wardrobe with pull-down rail, mobile patient hoist.

Entrance and floors

Level changes

The ramp in the Accessible step (length and landings by rule), portable threshold ramp, vertical platform lift for the entrance, home lift with cabin, stairlift with seat.

Wayfinding

For people with visual impairments

Tactile guidance and warning paving (for public plans such as shops, offices and schools) and a corridor handrail at two heights.

Mobility

Space planning

Wheelchair and rollator (wheeled walker): place them and check whether they get through doors, corridors and between furniture.

What it is not

The accessibility check informs; it doesn't replace a design

The Accessible step helps you ask the right questions at the start of the design and spot obvious gaps. Whether a home is truly usable also depends on the person's needs: a powered wheelchair needs more room to turn, and for someone with a visual impairment, colour contrast and lighting matter. In building permit and occupancy permit processes, the licensed architect's design and the authorities' opinion are what count.

Nodaform doesn't hide this limit: the rule set, source and assumptions used by the check are shown in the results panel. A red warning must always be dealt with; a green result, on the other hand, doesn't mean "everything is fine".

Does
Turning circle in every room, door clear opening and latch side, wheelchair route and narrow points from the entrance to the rooms, space beside the toilet, along the bed and in front of worktops, entrance level and ramp slope, lifts between floors
Doesn't
Threshold and floor materials, colour contrast and lighting, door handle and switch heights, grab bar mounting loads, lift design
Assumptions
The clear opening is calculated from the door opening minus the frame and leaf allowance (hinged 10, sliding 5, folding 15 cm); furniture counts as an obstacle, but the space in front of a washbasin or worktop with knee space, wall cabinets and bars do not
Proper use
Test the draft, clear the red items, and review the plan with the person who will use it and with your specialist
Open to everyone

The Accessible step is free on all plans

So that someone adapting their home for a relative with a disability doesn't hit a paywall, the check, the on-plan display, ramps and the 23 objects in the Accessible living category are also available on the Free plan. Draw your plan, check it and save it with a free account.

FAQ

Frequently asked questions

How wide should a door be for a wheelchair?

What's measured is the clear opening with the leaf open at 90°. In Turkey, the Planned Areas Zoning Regulation requires at least 100 cm for the apartment entrance door and at least 90 cm for interior doors; the Ministry's guide recommends leaving door openings of 110 and 100 cm to achieve this. In Germany, interior doors are 80 cm clear (90 cm in wheelchair-accessible housing), in England 75–85 cm, in the US 81.5 cm.

How much turning space does a wheelchair need?

The common dimension is a circle 150 cm in diameter (152.5 cm in the US). Germany's basic level accepts 120 × 120 cm. In the bathroom, kitchen, bedroom and entrance this space should be kept free of furniture; for powered wheelchairs, the guide in Turkey recommends 180 cm, preferably 210 cm.

What slope should an accessible ramp have?

In Turkey it depends on the height: 8% up to 15 cm, 7% for 16–50 cm, 6% for 51–100 cm and 5% above that; a landing every 9 m and handrails on both sides at 90 and 70 cm. In Germany at most 6% with a landing every 6 m, in the US at most 1:12 (8.33%). For example, in Turkey an entrance 45 cm high needs a ramp about 6.4 m long at 7%, with a landing at the top.

How much space should there be beside the toilet in an accessible toilet room?

To transfer sideways from a wheelchair, in Turkey and in Germany (in wheelchair-accessible housing) at least 90 cm of free space is left on one side of the toilet; in Germany this space is 70 cm deep. The toilet seat height is 43–48 cm, and a folding grab bar is fitted beside it.

Can a home have door thresholds?

In Turkey, thresholds aren't allowed at doors; according to the guide, a level difference of up to 0.6 cm is permitted, and up to 1.3 cm it must be bevelled. In Germany there are no thresholds at doors inside the apartment, in England at most 1.5 cm, in the US 1.3 cm.

Is the Accessible step a paid feature?

No. The check, the on-plan display, ramps and the 23 objects in the Accessible living category are available on all plans, including Free.

Is the check result enough for a building permit?

No. The Accessible step is for information only; it doesn't replace an accessibility design or the opinion of a licensed architect, engineer or the authorities. The rule set and assumptions the check uses are shown in the results panel.

Start

Draw a home everyone can move around easily, to scale.

Create a free account, draw your floor to scale and check it in the Accessible step. Ramps and accessible objects are free too.

Accessible objects