What is plinth height?
In everyday Turkish, “su basman” or “subasman” describes how high the ground floor slab is above the ground outside. Türkiye’s Planned Areas Zoning Regulation defines it as the subasman kotu (ground floor base level): the top level of the building’s ground floor slab (article 4).
The part below the plinth height is the building’s wall between the foundation and the ground floor slab; the ground floor sits on top of this wall.
Where is the ±0.00 level taken from?
The plinth is measured from ±0.00, the building’s reference point; if the level is taken from the road, this is the highest sidewalk level in line with the building corners. In Türkiye, on most lots the level is taken from the road:
- ±0.00 is the highest sidewalk level in line with the building corners on the road frontage the lot takes its level from (article 11/1).
- The sidewalk level is taken as 0.18 m above the road level set by the zoning plan’s road (red) level (article 11/2).
- In some cases listed in the regulation, the level is taken from natural ground; then ±0.00 is the arithmetic mean of the building’s corner levels (article 12/4).
In architectural drawings, the finished ground floor is often drawn as ±0.00; the zoning level and the ground are then written as negative values (ground −0.60 in the example). To avoid mixing up the two ±0.00s, the level of the reference point is also stated separately in the drawings.
What is the maximum plinth height?
In Türkiye, unless the zoning plan says otherwise, the plinth level cannot be below ±0.00 or above +1.20 (article 4). So the ground floor slab sits between 0 and 120 cm above the reference point. The zoning plan can change this range; always read the plan notes and the zoning status certificate.
The regulation gives zero as the minimum plinth height; the answer to “how many cm should it be” depends on the site, water and the entrance. The sections below cover the reasons behind this choice.
Why is the plinth raised? Damp, splashing and floods
If the ground floor sits right on the ground, rainwater, splashing water and ground moisture reach the walls and the floor. Country rules call for height and slope to prevent this:
- England: the damp-proof course in the wall is at least 150 mm above the adjoining ground (Approved Document C, 5.5).
- US: the ground falls at least 6 in (≈ 15 cm) within the first 10 ft (≈ 3 m) away from the building; at least 2% on hard surfaces (IRC R401.3). In flood hazard areas, the lowest floor is at least 1 ft (≈ 30 cm) above the base flood elevation (IRC R322.2.1).
- Germany: in the splash zone, waterproofing is taken 30 cm above the ground; the standard’s minimum is 15 cm (DIN 18533; explanation by the City of Dresden).
In Türkiye, the regulation requires measures in flood-risk areas but gives no general height; for such a lot, get the opinion of the municipality and the relevant authorities. On sites with high groundwater, on slopes or below road level, the plinth is often raised too.
Plinth and entrance: how many steps, how much ramp?
The higher the plinth, the more steps and the longer the ramp the entrance needs; for example, for a 60 cm plinth, 4 risers × 15 cm or a ramp with a horizontal length of 10.00 m. In Türkiye, risers on building stairs are at most 16 cm in buildings without an elevator (article 31/2); the maximum ramp slope depends on the rise: 8% up to 15 cm, 7% for 16–50 cm, 6% for 51–100 cm, 5% above 100 cm (article 30/12). Ramps longer than 9 m need a landing of at least 150 × 150 cm every 9 m (Accessibility Guide).
| Plinth | Riser | Ramp slope | Horizontal ramp length |
|---|---|---|---|
| 15 cm | 1 × 15 cm | %8 | 1.88 m |
| 30 cm | 2 × 15 cm | %7 | 4.29 m |
| 45 cm | 3 × 15 cm | %7 | 6.43 m |
| 60 cm | 4 × 15 cm | %6 | 10.00 m (with a landing) |
| 90 cm | 6 × 15 cm | %6 | 15.00 m (with a landing) |
| 120 cm | 8 × 15 cm | %5 | 24.00 m (with landings) |
In England, if an unavoidable step is needed at the entrance of a new home, it is at most 150 mm; an accessible threshold is at most 15 mm in total (Approved Document M, 1.14). As the table shows, a low plinth makes a step-free entrance much easier; with a high plinth, the ramp is often drawn along the building or turning in an L or U shape.
What to consider when choosing the plinth height
- Zoning status: the reference point and the permitted range (in Türkiye usually between ±0.00 and +1.20).
- Site: the slope, whether it’s higher or lower than the road, and rainwater draining away from the building.
- Water: flood risk, groundwater, splash allowance (at least 15–30 cm).
- Entrance: the number of steps and the ramp length; a low plinth if you want a step-free entrance.
- Basement: basement windows and daylight get easier as the plinth gets higher.
Plinth height in Nodaform
In Nodaform, you enter the plinth in the Plinth field of the Site step (on every plan): 0, 15, 30, 45, 60 and 90 cm are ready-made buttons, and you can type up to 300 cm. In 3D the building sits on a base at this height; in elevations and sections the ground line is drawn accordingly. In the plan, the ground floor slab is marked ±0.00, and if there’s a plinth, the ground level appears outside the entrance door.
The Entrance tool calculates the number of steps from the plinth, with risers of no more than 16 cm; the Accessible step takes the entrance height from the same value and checks the ramp slope against the rule set you choose. The editor doesn’t know the ±0.00 in the zoning plan or Türkiye’s +1.20 limit; enter the plinth yourself according to the zoning status.
The rules in this post were checked against official texts on 20 November 2026 (Planned Areas Zoning Regulation articles 4, 11, 12, 30 and 31; England’s Approved Document C and M; the US 2021 IRC; the City of Dresden’s explanation of DIN 18533). The reference point and the plinth height can vary with the zoning plan and zoning status; get the zoning status certificate from the municipality before you start the project.